v3.4.0 Changelog

v3.4.0

Released: 2024-12-02

characteristics

  • [characteristics] [bugfix]

    Date: 2024-09-24

    Title: Fix Hot Water Fixtures multipliers

    Description: Mean-shift hot water usage multipliers distribution by increasing weighted average from 0.8 to 1.0 in Hot Water Fixtures.tsv.

    resstock-estimation: pull request 420

    Assignees: Lixi Liu

    References: #1236, pull request 1265

  • [characteristics] [bugfix] [floor area]

    Date: 2024-09-23

    Title: Fix RECS floor area bins

    Description: RECS have been using incorrect floor area bins when assigning some characteristics due to a bug on how floor area bin is calculated. This PR fixes the issue.

    resstock-estimation: pull request 424

    Assignees: Rajendra Adhikari, Anthony Fontanini

    References: #1273, pull request 1301

workflow

  • [workflow] [feature] [hot water]

    Date: 2024-09-04

    Title: Latest OS-HPXML

    Description: For hot water end uses OS-HPXML now directly uses equations from https://www.fsec.ucf.edu/en/publications/pdf/fsec-pf-464-15.pdf, that are a function of number of occupants, for operational calculations.

    OpenStudio-HPXML: pull request 1761

    Assignees: Joe Robertson

    References: pull request 1282

  • [workflow] [feature] [plug loads]

    Date: 2024-09-26

    Title: Latest OS-HPXML

    Description: For TV plug loads, we are now using OS-HPXML defaults that directly use equations from RECS 2020 that are a function of number of occupants and conditioned floor area. For operational calculations in general, we are also updating the relationships between number of bedrooms/occupants based on RECS 2020 and disaggregated by building types.

    OpenStudio-HPXML: pull request 1690, pull request 1775

    Assignees: Joe Robertson

    References: pull request 1298

  • [workflow] [feature] [hvac]

    Date: 2024-09-27

    Title: Heating and Cooling Unavailable Days

    Description: The purpose of this PR is to account for dwelling units whose HVAC system (heating/cooling) is unavailable for some number of days during the year (per RECS 2020). Specifically, this PR modifies HVAC heating/cooling seasons using number of unavailable days and BAHSP definition for heating/cooling months.

    resstock-estimation: pull request 416

    Assignees: Joe Robertson

    References: pull request 1254

  • [workflow] [feature] [hvac]

    Date: 2024-11-14

    Title: Assign above-grade height for apartment units

    Description: The purpose of this PR is to set a value in ResStockArguments for apartment units based on the type/size of MF building and where the unit is located (lower, middle, or upper story).

    References: #1303, pull request 1304

  • [workflow] [bugfix] [infiltration]

    Date: 2024-08-20

    Title: Air leakage type “unit total”

    Description: Update options_lookup and ResStockArguments to use “unit total” air leakage type instead of the current “unit exterior only” type w/ infiltration adjustment approach. Modeled infiltration for dwelling units now have an upper bound equal to the sampled ACH50 option. Update BuildExistingModel to register adjusted total infiltration ACH50 value.

    Assignees: Joe Robertson

    References: pull request 1257

software

  • [software] [feature] [openstudio]

    Date: 2024-11-19

    Title: Latest OS-HPXML

    Description: Update to OpenStudio-HPXML 1.9/OpenStudio 3.9/EnergyPlus 24.2.

    OpenStudio-HPXML: pull request 1883

    Assignees: Joe Robertson, Scott Horowitz

    References: pull request 1318