Optional Outputs

Optional outputs include annual component loads, emissions, utility bills, and quantities of interest. Additionally, timeseries outputs can be requested.

To be generated, some optional outputs need only a single switch enabled (e.g., component loads). Others need additional input arguments specified (e.g., emissions, utility bills).

Note that enabling a set of optional outputs will by default generate the entire set. For example, requesting emissions outputs will result in columns for totals by fuel and by end use. There is currently no way to request totals by fuel while excluding totals by end use.

Component Loads

Component loads represent the estimated contribution of different building components to the annual heating/cooling building loads.

report_simulation_output.component_load_cooling_ceilings_m_btu
report_simulation_output.component_load_cooling_doors_m_btu
report_simulation_output.component_load_cooling_ducts_m_btu
report_simulation_output.component_load_cooling_floors_m_btu
report_simulation_output.component_load_cooling_foundation_walls_m_btu
report_simulation_output.component_load_cooling_infiltration_m_btu
report_simulation_output.component_load_cooling_internal_gains_m_btu
report_simulation_output.component_load_cooling_internal_mass_m_btu
report_simulation_output.component_load_cooling_lighting_m_btu
report_simulation_output.component_load_cooling_mechanical_ventilation_m_btu
report_simulation_output.component_load_cooling_natural_ventilation_m_btu
report_simulation_output.component_load_cooling_rim_joists_m_btu
report_simulation_output.component_load_cooling_roofs_m_btu
report_simulation_output.component_load_cooling_skylights_conduction_m_btu
report_simulation_output.component_load_cooling_skylights_solar_m_btu
report_simulation_output.component_load_cooling_slabs_m_btu
report_simulation_output.component_load_cooling_walls_m_btu
report_simulation_output.component_load_cooling_whole_house_fan_m_btu
report_simulation_output.component_load_cooling_windows_conduction_m_btu
report_simulation_output.component_load_cooling_windows_solar_m_btu
report_simulation_output.component_load_heating_ceilings_m_btu
report_simulation_output.component_load_heating_doors_m_btu
report_simulation_output.component_load_heating_ducts_m_btu
report_simulation_output.component_load_heating_floors_m_btu
report_simulation_output.component_load_heating_foundation_walls_m_btu
report_simulation_output.component_load_heating_infiltration_m_btu
report_simulation_output.component_load_heating_internal_gains_m_btu
report_simulation_output.component_load_heating_internal_mass_m_btu
report_simulation_output.component_load_heating_lighting_m_btu
report_simulation_output.component_load_heating_mechanical_ventilation_m_btu
report_simulation_output.component_load_heating_natural_ventilation_m_btu
report_simulation_output.component_load_heating_rim_joists_m_btu
report_simulation_output.component_load_heating_roofs_m_btu
report_simulation_output.component_load_heating_skylights_conduction_m_btu
report_simulation_output.component_load_heating_skylights_solar_m_btu
report_simulation_output.component_load_heating_slabs_m_btu
report_simulation_output.component_load_heating_walls_m_btu
report_simulation_output.component_load_heating_whole_house_fan_m_btu
report_simulation_output.component_load_heating_windows_conduction_m_btu
report_simulation_output.component_load_heating_windows_solar_m_btu

These outputs require that only a single switch is enabled. See the Residential HPXML Workflow Generator documentation page (i.e., build_existing_model section) for more information.

See the OpenStudio-HPXML Workflow Outputs section on Annual Component Building Loads for more information about component loads.

Emissions

Optional emissions outputs include annual total, by fuel, and by end use, for each emissions scenario requested. See the Residential HPXML Workflow Generator documentation page (i.e., emissions section) for more information on how to request emissions outputs by scenario.

See the OpenStudio-HPXML Workflow Outputs section on Annual Emissions for more information about annual emissions.

For the example below, the “LRMER_MidCase_15” emissions scenario was requested. See the list of available emissions scenario choices at https://github.com/NREL/resstock/tree/develop/resources/data/cambium.

report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_ceiling_fan_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_clothes_dryer_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_clothes_washer_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_cooling_fans_pumps_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_cooling_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_dehumidifier_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_dishwasher_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_electric_vehicle_charging_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_freezer_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_heating_fans_pumps_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_heating_heat_pump_backup_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_heating_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_hot_tub_heater_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_hot_tub_pump_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_hot_water_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_hot_water_recirc_pump_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_hot_water_solar_thermal_pump_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_lighting_exterior_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_lighting_garage_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_lighting_interior_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_mech_vent_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_plug_loads_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_pool_heater_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_pool_pump_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_pv_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_range_oven_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_refrigerator_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_total_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_electricity_well_pump_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_fuel_oil_heating_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_fuel_oil_hot_water_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_fuel_oil_total_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_natural_gas_clothes_dryer_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_natural_gas_fireplace_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_natural_gas_grill_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_natural_gas_heating_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_natural_gas_hot_tub_heater_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_natural_gas_hot_water_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_natural_gas_lighting_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_natural_gas_pool_heater_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_natural_gas_range_oven_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_natural_gas_total_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_propane_clothes_dryer_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_propane_heating_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_propane_hot_water_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_propane_range_oven_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_propane_total_lb
report_simulation_output.emissions_co_2_e_lrmer_mid_case_15_total_lb

Utility Bills

Optional utility bill outputs include annual fixed and marginal costs (total, by fuel type), and PV credits for electricity, for each utility bill scenario requested. See the Residential HPXML Workflow Generator documentation page (i.e., utility_bills section) for more information on how to request utility bill outputs by scenario.

See the OpenStudio-HPXML Workflow Outputs section on Utility Bill Outputs for more information about utility bill outputs.

report_utility_bills.bills_electricity_energy_usd
report_utility_bills.bills_electricity_fixed_usd
report_utility_bills.bills_electricity_pv_credit_usd
report_utility_bills.bills_electricity_total_usd
report_utility_bills.bills_fuel_oil_energy_usd
report_utility_bills.bills_fuel_oil_total_usd
report_utility_bills.bills_natural_gas_energy_usd
report_utility_bills.bills_natural_gas_fixed_usd
report_utility_bills.bills_natural_gas_total_usd
report_utility_bills.bills_propane_energy_usd
report_utility_bills.bills_propane_total_usd
report_utility_bills.bills_total_usd

Quantities of Interest

These outputs require that only a single switch is enabled. See the Residential HPXML Workflow Generator documentation page (i.e., reporting_measures section) for more information on how to request quantities of interest outputs.

qoi_report.qoi_average_maximum_daily_timing_cooling_hour
qoi_report.qoi_average_maximum_daily_timing_heating_hour
qoi_report.qoi_average_maximum_daily_timing_overlap_hour
qoi_report.qoi_average_maximum_daily_use_cooling_kw
qoi_report.qoi_average_maximum_daily_use_heating_kw
qoi_report.qoi_average_maximum_daily_use_overlap_kw
qoi_report.qoi_average_minimum_daily_use_cooling_kw
qoi_report.qoi_average_minimum_daily_use_heating_kw
qoi_report.qoi_average_minimum_daily_use_overlap_kw
qoi_report.qoi_average_of_top_ten_highest_peaks_timing_cooling_hour
qoi_report.qoi_average_of_top_ten_highest_peaks_timing_heating_hour
qoi_report.qoi_average_of_top_ten_highest_peaks_use_cooling_kw
qoi_report.qoi_average_of_top_ten_highest_peaks_use_heating_kw
qoi_report.qoi_peak_magnitude_timing_hour
qoi_report.qoi_peak_magnitude_use_kw

Timeseries

Specifying any timeseries frequency other than “none” results in, by default, end use consumptions and total loads timeseries output requests. See the Residential HPXML Workflow Generator documentation page (i.e., simulation_output_report section) for more information on how to request various timeseries outputs (or override default requests).