Optional Outputs
Optional outputs include component loads, emissions, utility bills, and quantities of interest. Other timeseries outputs related to zone temperatures/setpoints, airflow rates, weather file data, and user-requested EnergyPlus output variables can also be requested.
To be generated, some optional outputs need only a single switch enabled (e.g., component loads). Others need additional input arguments specified (e.g., emissions, utility bills). Again, see the Residential HPXML Workflow Generator documentation page for more information on how to enable optional output requests.
Component Loads
Component loads represent the estimated contribution of different building components to the annual heating/cooling building loads.
Annual Name |
Annual Units |
Timeseries ResStock Name |
Timeseries BuildStockBatch Name |
Timeseries Units |
Notes |
---|---|---|---|---|---|
report_simulation_output.component_load_cooling_ceilings_m_btu |
MBtu |
Component Load: Cooling: Ceilings |
component_load__cooling__ceilings__kbtu |
kBtu |
Heat gain/loss through HPXML Floor elements (inferred to be ceilings) adjacent to conditioned space |
report_simulation_output.component_load_cooling_doors_m_btu |
MBtu |
Component Load: Cooling: Doors |
component_load__cooling__doors__kbtu |
kBtu |
Heat gain/loss through HPXML Door elements adjacent to conditioned space |
report_simulation_output.component_load_cooling_ducts_m_btu |
MBtu |
Component Load: Cooling: Ducts |
component_load__cooling__ducts__kbtu |
kBtu |
Heat gain/loss from conduction and leakage losses through supply/return ducts outside conditioned space |
report_simulation_output.component_load_cooling_floors_m_btu |
MBtu |
Component Load: Cooling: Floors |
component_load__cooling__floors__kbtu |
kBtu |
Heat gain/loss through HPXML Floor elements (inferred to be floors) adjacent to conditioned space |
report_simulation_output.component_load_cooling_foundation_walls_m_btu |
MBtu |
Component Load: Cooling: Foundation Walls |
component_load__cooling__foundation_walls__kbtu |
kBtu |
Heat gain/loss through HPXML FoundationWall elements adjacent to conditioned space |
report_simulation_output.component_load_cooling_infiltration_m_btu |
MBtu |
Component Load: Cooling: Infiltration |
component_load__cooling__infiltration__kbtu |
kBtu |
Heat gain/loss from airflow induced by stack and wind effects |
report_simulation_output.component_load_cooling_internal_gains_m_btu |
MBtu |
Component Load: Cooling: Internal Gains |
component_load__cooling__internal_gains__kbtu |
kBtu |
Heat gain/loss from appliances, plug loads, water heater tank losses, etc. in the conditioned space |
report_simulation_output.component_load_cooling_internal_mass_m_btu |
MBtu |
Component Load: Cooling: Internal Mass |
component_load__cooling__internal_mass__kbtu |
kBtu |
Heat gain/loss from internal mass (e.g., furniture, interior walls/floors) in conditioned space |
report_simulation_output.component_load_cooling_lighting_m_btu |
MBtu |
Component Load: Cooling: Lighting |
component_load__cooling__lighting__kbtu |
kBtu |
Heat gain/loss from lighting in the conditioned space |
report_simulation_output.component_load_cooling_mechanical_ventilation_m_btu |
MBtu |
Component Load: Cooling: Mechanical Ventilation |
component_load__cooling__mechanical_ventilation__kbtu |
kBtu |
Heat gain/loss from airflow/fan energy from mechanical ventilation systems (including clothes dryer exhaust) |
report_simulation_output.component_load_cooling_natural_ventilation_m_btu |
MBtu |
Component Load: Cooling: Natural Ventilation |
component_load__cooling__natural_ventilation__kbtu |
kBtu |
Heat gain/loss from airflow through operable windows |
report_simulation_output.component_load_cooling_rim_joists_m_btu |
MBtu |
Component Load: Cooling: Rim Joists |
component_load__cooling__rim_joists__kbtu |
kBtu |
Heat gain/loss through HPXML RimJoist elements adjacent to conditioned space |
report_simulation_output.component_load_cooling_roofs_m_btu |
MBtu |
Component Load: Cooling: Roofs |
component_load__cooling__roofs__kbtu |
kBtu |
Heat gain/loss through HPXML Roof elements adjacent to conditioned space |
report_simulation_output.component_load_cooling_skylights_conduction_m_btu |
MBtu |
Component Load: Cooling: Skylights Conduction |
component_load__cooling__skylights_conduction__kbtu |
kBtu |
Heat gain/loss attributed to conduction through HPXML Skylight elements adjacent to conditioned space |
report_simulation_output.component_load_cooling_skylights_solar_m_btu |
MBtu |
Component Load: Cooling: Skylights Solar |
component_load__cooling__skylights_solar__kbtu |
kBtu |
Heat gain/loss attributed to solar gains through HPXML Skylight elements adjacent to conditioned space |
report_simulation_output.component_load_cooling_slabs_m_btu |
MBtu |
Component Load: Cooling: Slabs |
component_load__cooling__slabs__kbtu |
kBtu |
Heat gain/loss through HPXML Slab elements adjacent to conditioned space |
report_simulation_output.component_load_cooling_walls_m_btu |
MBtu |
Component Load: Cooling: Walls |
component_load__cooling__walls__kbtu |
kBtu |
Heat gain/loss through HPXML Wall elements adjacent to conditioned space |
report_simulation_output.component_load_cooling_whole_house_fan_m_btu |
MBtu |
Component Load: Cooling: Whole House Fan |
component_load__cooling__whole_house_fan__kbtu |
kBtu |
Heat gain/loss from airflow due to a whole house fan |
report_simulation_output.component_load_cooling_windows_conduction_m_btu |
MBtu |
Component Load: Cooling: Windows Conduction |
component_load__cooling__windows_conduction__kbtu |
kBtu |
Heat gain/loss attributed to conduction through HPXML Window elements adjacent to conditioned space |
report_simulation_output.component_load_cooling_windows_solar_m_btu |
MBtu |
Component Load: Cooling: Windows Solar |
component_load__cooling__windows_solar__kbtu |
kBtu |
Heat gain/loss attributed to solar gains through HPXML Window elements adjacent to conditioned space |
report_simulation_output.component_load_heating_ceilings_m_btu |
MBtu |
Component Load: Heating: Ceilings |
component_load__heating__ceilings__kbtu |
kBtu |
Heat gain/loss through HPXML Floor elements (inferred to be ceilings) adjacent to conditioned space |
report_simulation_output.component_load_heating_doors_m_btu |
MBtu |
Component Load: Heating: Doors |
component_load__heating__doors__kbtu |
kBtu |
Heat gain/loss through HPXML Door elements adjacent to conditioned space |
report_simulation_output.component_load_heating_ducts_m_btu |
MBtu |
Component Load: Heating: Ducts |
component_load__heating__ducts__kbtu |
kBtu |
Heat gain/loss from conduction and leakage losses through supply/return ducts outside conditioned space |
report_simulation_output.component_load_heating_floors_m_btu |
MBtu |
Component Load: Heating: Floors |
component_load__heating__floors__kbtu |
kBtu |
Heat gain/loss through HPXML Floor elements (inferred to be floors) adjacent to conditioned space |
report_simulation_output.component_load_heating_foundation_walls_m_btu |
MBtu |
Component Load: Heating: Foundation Walls |
component_load__heating__foundation_walls__kbtu |
kBtu |
Heat gain/loss through HPXML FoundationWall elements adjacent to conditioned space |
report_simulation_output.component_load_heating_infiltration_m_btu |
MBtu |
Component Load: Heating: Infiltration |
component_load__heating__infiltration__kbtu |
kBtu |
Heat gain/loss from airflow induced by stack and wind effects |
report_simulation_output.component_load_heating_internal_gains_m_btu |
MBtu |
Component Load: Heating: Internal Gains |
component_load__heating__internal_gains__kbtu |
kBtu |
Heat gain/loss from appliances, plug loads, water heater tank losses, etc. in the conditioned space |
report_simulation_output.component_load_heating_internal_mass_m_btu |
MBtu |
Component Load: Heating: Internal Mass |
component_load__heating__internal_mass__kbtu |
kBtu |
Heat gain/loss from internal mass (e.g., furniture, interior walls/floors) in conditioned space |
report_simulation_output.component_load_heating_lighting_m_btu |
MBtu |
Component Load: Heating: Lighting |
component_load__heating__lighting__kbtu |
kBtu |
Heat gain/loss from lighting in the conditioned space |
report_simulation_output.component_load_heating_mechanical_ventilation_m_btu |
MBtu |
Component Load: Heating: Mechanical Ventilation |
component_load__heating__mechanical_ventilation__kbtu |
kBtu |
Heat gain/loss from airflow/fan energy from mechanical ventilation systems (including clothes dryer exhaust) |
report_simulation_output.component_load_heating_natural_ventilation_m_btu |
MBtu |
Component Load: Heating: Natural Ventilation |
component_load__heating__natural_ventilation__kbtu |
kBtu |
Heat gain/loss from airflow through operable windows |
report_simulation_output.component_load_heating_rim_joists_m_btu |
MBtu |
Component Load: Heating: Rim Joists |
component_load__heating__rim_joists__kbtu |
kBtu |
Heat gain/loss through HPXML RimJoist elements adjacent to conditioned space |
report_simulation_output.component_load_heating_roofs_m_btu |
MBtu |
Component Load: Heating: Roofs |
component_load__heating__roofs__kbtu |
kBtu |
Heat gain/loss through HPXML Roof elements adjacent to conditioned space |
report_simulation_output.component_load_heating_skylights_conduction_m_btu |
MBtu |
Component Load: Heating: Skylights Conduction |
component_load__heating__skylights_conduction__kbtu |
kBtu |
Heat gain/loss attributed to conduction through HPXML Skylight elements adjacent to conditioned space |
report_simulation_output.component_load_heating_skylights_solar_m_btu |
MBtu |
Component Load: Heating: Skylights Solar |
component_load__heating__skylights_solar__kbtu |
kBtu |
Heat gain/loss attributed to solar gains through HPXML Skylight elements adjacent to conditioned space |
report_simulation_output.component_load_heating_slabs_m_btu |
MBtu |
Component Load: Heating: Slabs |
component_load__heating__slabs__kbtu |
kBtu |
Heat gain/loss through HPXML Slab elements adjacent to conditioned space |
report_simulation_output.component_load_heating_walls_m_btu |
MBtu |
Component Load: Heating: Walls |
component_load__heating__walls__kbtu |
kBtu |
Heat gain/loss through HPXML Wall elements adjacent to conditioned space |
report_simulation_output.component_load_heating_whole_house_fan_m_btu |
MBtu |
Component Load: Heating: Whole House Fan |
component_load__heating__whole_house_fan__kbtu |
kBtu |
Heat gain/loss from airflow due to a whole house fan |
report_simulation_output.component_load_heating_windows_conduction_m_btu |
MBtu |
Component Load: Heating: Windows Conduction |
component_load__heating__windows_conduction__kbtu |
kBtu |
Heat gain/loss attributed to conduction through HPXML Window elements adjacent to conditioned space |
report_simulation_output.component_load_heating_windows_solar_m_btu |
MBtu |
Component Load: Heating: Windows Solar |
component_load__heating__windows_solar__kbtu |
kBtu |
Heat gain/loss attributed to solar gains through HPXML Window elements adjacent to conditioned space |
These outputs require that only a single switch is enabled.
See the Residential HPXML Workflow Generator documentation page (i.e., build_existing_model
section) for more information.
See the OpenStudio-HPXML Workflow Outputs sections on Annual Component Building Loads and Timeseries Outputs for more information about component loads.
Emissions
Optional emissions outputs include annual total, by fuel, and by end use, for each emissions scenario requested.
See the Residential HPXML Workflow Generator documentation page (i.e., emissions
section) for more information on how to request emissions outputs by scenario.
See the OpenStudio-HPXML Workflow Outputs sections on Annual Emissions and Timeseries Outputs for more information about emissions.
In the table below, “<type>” refers to the type
of emission (e.g., “CO2e”, “NOx”, etc.) specified and “<scenario_name>” refers to the scenario_name
(e.g., “LRMER_MidCase_15”, “AER_HighRECost_1”, etc.) specified.
See the list of all available emissions scenario name choices at https://github.com/NREL/resstock/tree/develop/resources/data/cambium.
Note
Output names may show “<type>” and “<scenario_name>” in some form of “underscore” case. For example, “CO2e” may become “co2e” (or “co_2_e”) and “LRMER_MidCase_15” may become “lrmer_mid_case_15” (or “lrmer_midcase_15”).
Annual Name |
Annual Units |
Timeseries ResStock Name |
Timeseries BuildStockBatch Name |
Timeseries Units |
Notes |
---|---|---|---|---|---|
report_simulation_output.emissions_<type>_<scenario_name>_coal_clothes_dryer_lb |
lb |
Emissions: <type>: <scenario_name>: Coal: Clothes Dryer |
emissions__<type>__<scenario_name>__coal__clothes_dryer__lb |
lb |
Scenario emissions for this Coal end use only |
report_simulation_output.emissions_<type>_<scenario_name>_coal_fireplace_lb |
lb |
Emissions: <type>: <scenario_name>: Coal: Fireplace |
emissions__<type>__<scenario_name>__coal__fireplace__lb |
lb |
Scenario emissions for this Coal end use only |
report_simulation_output.emissions_<type>_<scenario_name>_coal_generator_lb |
lb |
Emissions: <type>: <scenario_name>: Coal: Generator |
emissions__<type>__<scenario_name>__coal__generator__lb |
lb |
Scenario emissions for this Coal end use only |
report_simulation_output.emissions_<type>_<scenario_name>_coal_grill_lb |
lb |
Emissions: <type>: <scenario_name>: Coal: Grill |
emissions__<type>__<scenario_name>__coal__grill__lb |
lb |
Scenario emissions for this Coal end use only |
report_simulation_output.emissions_<type>_<scenario_name>_coal_heating_heat_pump_backup_lb |
lb |
Emissions: <type>: <scenario_name>: Coal: Heating Heat Pump Backup |
emissions__<type>__<scenario_name>__coal__heating_heat_pump_backup__lb |
lb |
Scenario emissions for this Coal end use only |
report_simulation_output.emissions_<type>_<scenario_name>_coal_heating_lb |
lb |
Emissions: <type>: <scenario_name>: Coal: Heating |
emissions__<type>__<scenario_name>__coal__heating__lb |
lb |
Scenario emissions for this Coal end use only |
report_simulation_output.emissions_<type>_<scenario_name>_coal_hot_water_lb |
lb |
Emissions: <type>: <scenario_name>: Coal: Hot Water |
emissions__<type>__<scenario_name>__coal__hot_water__lb |
lb |
Scenario emissions for this Coal end use only |
report_simulation_output.emissions_<type>_<scenario_name>_coal_lighting_lb |
lb |
Emissions: <type>: <scenario_name>: Coal: Lighting |
emissions__<type>__<scenario_name>__coal__lighting__lb |
lb |
Scenario emissions for this Coal end use only |
report_simulation_output.emissions_<type>_<scenario_name>_coal_mech_vent_preheating_lb |
lb |
Emissions: <type>: <scenario_name>: Coal: Mech Vent Preheating |
emissions__<type>__<scenario_name>__coal__mech_vent_preheating__lb |
lb |
Scenario emissions for this Coal end use only |
report_simulation_output.emissions_<type>_<scenario_name>_coal_range_oven_lb |
lb |
Emissions: <type>: <scenario_name>: Coal: Range/Oven |
emissions__<type>__<scenario_name>__coal__range_oven__lb |
lb |
Scenario emissions for this Coal end use only |
report_simulation_output.emissions_<type>_<scenario_name>_coal_total_lb |
lb |
Emissions: <type>: <scenario_name>: Coal: Total |
emissions__<type>__<scenario_name>__coal__total__lb |
lb |
Scenario emissions for Coal only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_battery_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Battery |
emissions__<type>__<scenario_name>__electricity__battery__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_ceiling_fan_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Ceiling Fan |
emissions__<type>__<scenario_name>__electricity__ceiling_fan__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_clothes_dryer_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Clothes Dryer |
emissions__<type>__<scenario_name>__electricity__clothes_dryer__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_clothes_washer_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Clothes Washer |
emissions__<type>__<scenario_name>__electricity__clothes_washer__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_cooling_fans_pumps_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Cooling Fans/Pumps |
emissions__<type>__<scenario_name>__electricity__cooling_fans_pumps__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_cooling_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Cooling |
emissions__<type>__<scenario_name>__electricity__cooling__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_dehumidifier_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Dehumidifier |
emissions__<type>__<scenario_name>__electricity__dehumidifier__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_dishwasher_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Dishwasher |
emissions__<type>__<scenario_name>__electricity__dishwasher__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_electric_vehicle_charging_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Electric Vehicle Charging |
emissions__<type>__<scenario_name>__electricity__electric_vehicle_charging__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_freezer_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Freezer |
emissions__<type>__<scenario_name>__electricity__freezer__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_generator_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Generator |
emissions__<type>__<scenario_name>__electricity__generator__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_heating_fans_pumps_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Heating Fans/Pumps |
emissions__<type>__<scenario_name>__electricity__heating_fans_pumps__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_heating_heat_pump_backup_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Heating Heat Pump Backup |
emissions__<type>__<scenario_name>__electricity__heating_heat_pump_backup__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_heating_heat_pump_backup_fans_pumps_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Heating Heat Pump Backup Fans/Pumps |
emissions__<type>__<scenario_name>__electricity__heating_heat_pump_backup_fans_pumps__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_heating_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Heating |
emissions__<type>__<scenario_name>__electricity__heating__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_permanent_spa_heater_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Permanent Spa Heater |
emissions__<type>__<scenario_name>__electricity__permanent_spa_heater__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_permanent_spa_pump_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Permanent Spa Pump |
emissions__<type>__<scenario_name>__electricity__permanent_spa_pump__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_hot_water_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Hot Water |
emissions__<type>__<scenario_name>__electricity__hot_water__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_hot_water_recirc_pump_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Hot Water Recirc Pump |
emissions__<type>__<scenario_name>__electricity__hot_water_recirc_pump__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_hot_water_solar_thermal_pump_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Hot Water Solar Thermal Pump |
emissions__<type>__<scenario_name>__electricity__hot_water_solar_thermal_pump__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_lighting_exterior_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Lighting Exterior |
emissions__<type>__<scenario_name>__electricity__lighting_exterior__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_lighting_garage_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Lighting Garage |
emissions__<type>__<scenario_name>__electricity__lighting_garage__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_lighting_interior_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Lighting Interior |
emissions__<type>__<scenario_name>__electricity__lighting_interior__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_mech_vent_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Mech Vent |
emissions__<type>__<scenario_name>__electricity__mech_vent__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_mech_vent_precooling_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Mech Vent Precooling |
emissions__<type>__<scenario_name>__electricity__mech_vent_precooling__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_mech_vent_preheating_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Mech Vent Preheating |
emissions__<type>__<scenario_name>__electricity__mech_vent_preheating__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_net_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Net |
emissions__<type>__<scenario_name>__electricity__net__lb |
lb |
Subtracts any power produced by PV or generators |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_plug_loads_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Plug Loads |
emissions__<type>__<scenario_name>__electricity__plug_loads__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_pool_heater_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Pool Heater |
emissions__<type>__<scenario_name>__electricity__pool_heater__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_pool_pump_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Pool Pump |
emissions__<type>__<scenario_name>__electricity__pool_pump__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_pv_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: PV |
emissions__<type>__<scenario_name>__electricity__pv__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_range_oven_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Range/Oven |
emissions__<type>__<scenario_name>__electricity__range_oven__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_refrigerator_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Refrigerator |
emissions__<type>__<scenario_name>__electricity__refrigerator__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_television_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Television |
emissions__<type>__<scenario_name>__electricity__television__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_total_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Total |
emissions__<type>__<scenario_name>__electricity__total__lb |
lb |
Scenario total emissions for Electricity only, includes any battery charging/discharging |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_well_pump_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Well Pump |
emissions__<type>__<scenario_name>__electricity__well_pump__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_electricity_whole_house_fan_lb |
lb |
Emissions: <type>: <scenario_name>: Electricity: Whole House Fan |
emissions__<type>__<scenario_name>__electricity__whole_house_fan__lb |
lb |
Scenario emissions for this Electricity end use only |
report_simulation_output.emissions_<type>_<scenario_name>_fuel_oil_clothes_dryer_lb |
lb |
Emissions: <type>: <scenario_name>: Fuel Oil: Clothes Dryer |
emissions__<type>__<scenario_name>__fuel_oil__clothes_dryer__lb |
lb |
Scenario emissions for this Fuel Oil end use only |
report_simulation_output.emissions_<type>_<scenario_name>_fuel_oil_fireplace_lb |
lb |
Emissions: <type>: <scenario_name>: Fuel Oil: Fireplace |
emissions__<type>__<scenario_name>__fuel_oil__fireplace__lb |
lb |
Scenario emissions for this Fuel Oil end use only |
report_simulation_output.emissions_<type>_<scenario_name>_fuel_oil_generator_lb |
lb |
Emissions: <type>: <scenario_name>: Fuel Oil: Generator |
emissions__<type>__<scenario_name>__fuel_oil__generator__lb |
lb |
Scenario emissions for this Fuel Oil end use only |
report_simulation_output.emissions_<type>_<scenario_name>_fuel_oil_grill_lb |
lb |
Emissions: <type>: <scenario_name>: Fuel Oil: Grill |
emissions__<type>__<scenario_name>__fuel_oil__grill__lb |
lb |
Scenario emissions for this Fuel Oil end use only |
report_simulation_output.emissions_<type>_<scenario_name>_fuel_oil_heating_heat_pump_backup_lb |
lb |
Emissions: <type>: <scenario_name>: Fuel Oil: Heating Heat Pump Backup |
emissions__<type>__<scenario_name>__fuel_oil__heating_heat_pump_backup__lb |
lb |
Scenario emissions for this Fuel Oil end use only |
report_simulation_output.emissions_<type>_<scenario_name>_fuel_oil_heating_lb |
lb |
Emissions: <type>: <scenario_name>: Fuel Oil: Heating |
emissions__<type>__<scenario_name>__fuel_oil__heating__lb |
lb |
Scenario emissions for this Fuel Oil end use only |
report_simulation_output.emissions_<type>_<scenario_name>_fuel_oil_hot_water_lb |
lb |
Emissions: <type>: <scenario_name>: Fuel Oil: Hot Water |
emissions__<type>__<scenario_name>__fuel_oil__hot_water__lb |
lb |
Scenario emissions for this Fuel Oil end use only |
report_simulation_output.emissions_<type>_<scenario_name>_fuel_oil_lighting_lb |
lb |
Emissions: <type>: <scenario_name>: Fuel Oil: Lighting |
emissions__<type>__<scenario_name>__fuel_oil__lighting__lb |
lb |
Scenario emissions for this Fuel Oil end use only |
report_simulation_output.emissions_<type>_<scenario_name>_fuel_oil_mech_vent_preheating_lb |
lb |
Emissions: <type>: <scenario_name>: Fuel Oil: Mech Vent Preheating |
emissions__<type>__<scenario_name>__fuel_oil__mech_vent_preheating__lb |
lb |
Scenario emissions for this Fuel Oil end use only |
report_simulation_output.emissions_<type>_<scenario_name>_fuel_oil_range_oven_lb |
lb |
Emissions: <type>: <scenario_name>: Fuel Oil: Range/Oven |
emissions__<type>__<scenario_name>__fuel_oil__range_oven__lb |
lb |
Scenario emissions for this Fuel Oil end use only |
report_simulation_output.emissions_<type>_<scenario_name>_fuel_oil_total_lb |
lb |
Emissions: <type>: <scenario_name>: Fuel Oil: Total |
emissions__<type>__<scenario_name>__fuel_oil__total__lb |
lb |
Scenario emissions for Fuel Oil only |
report_simulation_output.emissions_<type>_<scenario_name>_natural_gas_clothes_dryer_lb |
lb |
Emissions: <type>: <scenario_name>: Natural Gas: Clothes Dryer |
emissions__<type>__<scenario_name>__natural_gas__clothes_dryer__lb |
lb |
Scenario emissions for this Natural Gas end use only |
report_simulation_output.emissions_<type>_<scenario_name>_natural_gas_fireplace_lb |
lb |
Emissions: <type>: <scenario_name>: Natural Gas: Fireplace |
emissions__<type>__<scenario_name>__natural_gas__fireplace__lb |
lb |
Scenario emissions for this Natural Gas end use only |
report_simulation_output.emissions_<type>_<scenario_name>_natural_gas_generator_lb |
lb |
Emissions: <type>: <scenario_name>: Natural Gas: Generator |
emissions__<type>__<scenario_name>__natural_gas__generator__lb |
lb |
Scenario emissions for this Natural Gas end use only |
report_simulation_output.emissions_<type>_<scenario_name>_natural_gas_grill_lb |
lb |
Emissions: <type>: <scenario_name>: Natural Gas: Grill |
emissions__<type>__<scenario_name>__natural_gas__grill__lb |
lb |
Scenario emissions for this Natural Gas end use only |
report_simulation_output.emissions_<type>_<scenario_name>_natural_gas_heating_heat_pump_backup_lb |
lb |
Emissions: <type>: <scenario_name>: Natural Gas: Heating Heat Pump Backup |
emissions__<type>__<scenario_name>__natural_gas__heating_heat_pump_backup__lb |
lb |
Scenario emissions for this Natural Gas end use only |
report_simulation_output.emissions_<type>_<scenario_name>_natural_gas_heating_lb |
lb |
Emissions: <type>: <scenario_name>: Natural Gas: Heating |
emissions__<type>__<scenario_name>__natural_gas__heating__lb |
lb |
Scenario emissions for this Natural Gas end use only |
report_simulation_output.emissions_<type>_<scenario_name>_natural_gas_permanent_spa_heater_lb |
lb |
Emissions: <type>: <scenario_name>: Natural Gas: Permanent Spa Heater |
emissions__<type>__<scenario_name>__natural_gas__permanent_spa_heater__lb |
lb |
Scenario emissions for this Natural Gas end use only |
report_simulation_output.emissions_<type>_<scenario_name>_natural_gas_hot_water_lb |
lb |
Emissions: <type>: <scenario_name>: Natural Gas: Hot Water |
emissions__<type>__<scenario_name>__natural_gas__hot_water__lb |
lb |
Scenario emissions for this Natural Gas end use only |
report_simulation_output.emissions_<type>_<scenario_name>_natural_gas_lighting_lb |
lb |
Emissions: <type>: <scenario_name>: Natural Gas: Lighting |
emissions__<type>__<scenario_name>__natural_gas__lighting__lb |
lb |
Scenario emissions for this Natural Gas end use only |
report_simulation_output.emissions_<type>_<scenario_name>_natural_gas_mech_vent_preheating_lb |
lb |
Emissions: <type>: <scenario_name>: Natural Gas: Mech Vent Preheating |
emissions__<type>__<scenario_name>__natural_gas__mech_vent_preheating__lb |
lb |
Scenario emissions for this Natural Gas end use only |
report_simulation_output.emissions_<type>_<scenario_name>_natural_gas_pool_heater_lb |
lb |
Emissions: <type>: <scenario_name>: Natural Gas: Pool Heater |
emissions__<type>__<scenario_name>__natural_gas__pool_heater__lb |
lb |
Scenario emissions for this Natural Gas end use only |
report_simulation_output.emissions_<type>_<scenario_name>_natural_gas_range_oven_lb |
lb |
Emissions: <type>: <scenario_name>: Natural Gas: Range/Oven |
emissions__<type>__<scenario_name>__natural_gas__range_oven__lb |
lb |
Scenario emissions for this Natural Gas end use only |
report_simulation_output.emissions_<type>_<scenario_name>_natural_gas_total_lb |
lb |
Emissions: <type>: <scenario_name>: Natural Gas: Total |
emissions__<type>__<scenario_name>__natural_gas__total__lb |
lb |
Scenario emissions for Natural Gas only |
report_simulation_output.emissions_<type>_<scenario_name>_net_lb |
lb |
Emissions: <type>: <scenario_name>: Net |
emissions__<type>__<scenario_name>__net__lb |
lb |
Subtracts any power produced by PV or generators |
report_simulation_output.emissions_<type>_<scenario_name>_propane_clothes_dryer_lb |
lb |
Emissions: <type>: <scenario_name>: Propane: Clothes Dryer |
emissions__<type>__<scenario_name>__propane__clothes_dryer__lb |
lb |
Scenario emissions for this Propane end use only |
report_simulation_output.emissions_<type>_<scenario_name>_propane_fireplace_lb |
lb |
Emissions: <type>: <scenario_name>: Propane: Fireplace |
emissions__<type>__<scenario_name>__propane__fireplace__lb |
lb |
Scenario emissions for this Propane end use only |
report_simulation_output.emissions_<type>_<scenario_name>_propane_generator_lb |
lb |
Emissions: <type>: <scenario_name>: Propane: Generator |
emissions__<type>__<scenario_name>__propane__generator__lb |
lb |
Scenario emissions for this Propane end use only |
report_simulation_output.emissions_<type>_<scenario_name>_propane_grill_lb |
lb |
Emissions: <type>: <scenario_name>: Propane: Grill |
emissions__<type>__<scenario_name>__propane__grill__lb |
lb |
Scenario emissions for this Propane end use only |
report_simulation_output.emissions_<type>_<scenario_name>_propane_heating_heat_pump_backup_lb |
lb |
Emissions: <type>: <scenario_name>: Propane: Heating Heat Pump Backup |
emissions__<type>__<scenario_name>__propane__heating_heat_pump_backup__lb |
lb |
Scenario emissions for this Propane end use only |
report_simulation_output.emissions_<type>_<scenario_name>_propane_heating_lb |
lb |
Emissions: <type>: <scenario_name>: Propane: Heating |
emissions__<type>__<scenario_name>__propane__heating__lb |
lb |
Scenario emissions for this Propane end use only |
report_simulation_output.emissions_<type>_<scenario_name>_propane_hot_water_lb |
lb |
Emissions: <type>: <scenario_name>: Propane: Hot Water |
emissions__<type>__<scenario_name>__propane__hot_water__lb |
lb |
Scenario emissions for this Propane end use only |
report_simulation_output.emissions_<type>_<scenario_name>_propane_lighting_lb |
lb |
Emissions: <type>: <scenario_name>: Propane: Lighting |
emissions__<type>__<scenario_name>__propane__lighting__lb |
lb |
Scenario emissions for this Propane end use only |
report_simulation_output.emissions_<type>_<scenario_name>_propane_mech_vent_preheating_lb |
lb |
Emissions: <type>: <scenario_name>: Propane: Mech Vent Preheating |
emissions__<type>__<scenario_name>__propane__mech_vent_preheating__lb |
lb |
Scenario emissions for this Propane end use only |
report_simulation_output.emissions_<type>_<scenario_name>_propane_range_oven_lb |
lb |
Emissions: <type>: <scenario_name>: Propane: Range/Oven |
emissions__<type>__<scenario_name>__propane__range_oven__lb |
lb |
Scenario emissions for this Propane end use only |
report_simulation_output.emissions_<type>_<scenario_name>_propane_total_lb |
lb |
Emissions: <type>: <scenario_name>: Propane: Total |
emissions__<type>__<scenario_name>__propane__total__lb |
lb |
Scenario emissions for Propane only |
report_simulation_output.emissions_<type>_<scenario_name>_total_lb |
lb |
Emissions: <type>: <scenario_name>: Total |
emissions__<type>__<scenario_name>__total__lb |
lb |
Scenario total emissions, includes any battery charging/discharging |
report_simulation_output.emissions_<type>_<scenario_name>_wood_cord_clothes_dryer_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Cord: Clothes Dryer |
emissions__<type>__<scenario_name>__wood_cord__clothes_dryer__lb |
lb |
Scenario emissions for this Wood Cord end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_cord_fireplace_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Cord: Fireplace |
emissions__<type>__<scenario_name>__wood_cord__fireplace__lb |
lb |
Scenario emissions for this Wood Cord end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_cord_generator_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Cord: Generator |
emissions__<type>__<scenario_name>__wood_cord__generator__lb |
lb |
Scenario emissions for this Wood Cord end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_cord_grill_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Cord: Grill |
emissions__<type>__<scenario_name>__wood_cord__grill__lb |
lb |
Scenario emissions for this Wood Cord end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_cord_heating_heat_pump_backup_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Cord: Heating Heat Pump Backup |
emissions__<type>__<scenario_name>__wood_cord__heating_heat_pump_backup__lb |
lb |
Scenario emissions for this Wood Cord end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_cord_heating_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Cord: Heating |
emissions__<type>__<scenario_name>__wood_cord__heating__lb |
lb |
Scenario emissions for this Wood Cord end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_cord_hot_water_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Cord: Hot Water |
emissions__<type>__<scenario_name>__wood_cord__hot_water__lb |
lb |
Scenario emissions for this Wood Cord end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_cord_lighting_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Cord: Lighting |
emissions__<type>__<scenario_name>__wood_cord__lighting__lb |
lb |
Scenario emissions for this Wood Cord end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_cord_mech_vent_preheating_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Cord: Mech Vent Preheating |
emissions__<type>__<scenario_name>__wood_cord__mech_vent_preheating__lb |
lb |
Scenario emissions for this Wood Cord end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_cord_range_oven_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Cord: Range/Oven |
emissions__<type>__<scenario_name>__wood_cord__range_oven__lb |
lb |
Scenario emissions for this Wood Cord end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_cord_total_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Cord: Total |
emissions__<type>__<scenario_name>__wood_cord__total__lb |
lb |
Scenario emissions for Wood Cord only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_pellets_clothes_dryer_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Pellets: Clothes Dryer |
emissions__<type>__<scenario_name>__wood_pellets__clothes_dryer__lb |
lb |
Scenario emissions for this Wood Pellets end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_pellets_fireplace_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Pellets: Fireplace |
emissions__<type>__<scenario_name>__wood_pellets__fireplace__lb |
lb |
Scenario emissions for this Wood Pellets end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_pellets_generator_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Pellets: Generator |
emissions__<type>__<scenario_name>__wood_pellets__generator__lb |
lb |
Scenario emissions for this Wood Pellets end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_pellets_grill_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Pellets: Grill |
emissions__<type>__<scenario_name>__wood_pellets__grill__lb |
lb |
Scenario emissions for this Wood Pellets end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_pellets_heating_heat_pump_backup_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Pellets: Heating Heat Pump Backup |
emissions__<type>__<scenario_name>__wood_pellets__heating_heat_pump_backup__lb |
lb |
Scenario emissions for this Wood Pellets end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_pellets_heating_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Pellets: Heating |
emissions__<type>__<scenario_name>__wood_pellets__heating__lb |
lb |
Scenario emissions for this Wood Pellets end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_pellets_hot_water_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Pellets: Hot Water |
emissions__<type>__<scenario_name>__wood_pellets__hot_water__lb |
lb |
Scenario emissions for this Wood Pellets end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_pellets_lighting_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Pellets: Lighting |
emissions__<type>__<scenario_name>__wood_pellets__lighting__lb |
lb |
Scenario emissions for this Wood Pellets end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_pellets_mech_vent_preheating_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Pellets: Mech Vent Preheating |
emissions__<type>__<scenario_name>__wood_pellets__mech_vent_preheating__lb |
lb |
Scenario emissions for this Wood Pellets end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_pellets_range_oven_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Pellets: Range/Oven |
emissions__<type>__<scenario_name>__wood_pellets__range_oven__lb |
lb |
Scenario emissions for this Wood Pellets end use only |
report_simulation_output.emissions_<type>_<scenario_name>_wood_pellets_total_lb |
lb |
Emissions: <type>: <scenario_name>: Wood Pellets: Total |
emissions__<type>__<scenario_name>__wood_pellets__total__lb |
lb |
Scenario emissions for Wood Pellets only |
Utility Bills
Optional utility bill outputs include annual fixed and marginal costs (total, by fuel type), and PV credits for electricity, for each utility bill scenario requested.
See the Residential HPXML Workflow Generator documentation page (i.e., utility_bills
section) for more information on how to request utility bill outputs by scenario.
See the OpenStudio-HPXML Workflow Outputs section on Utility Bill Outputs for more information about utility bill outputs.
In the table below, “<scenario_name>” refers to the scenario_name
(e.g., “Bills”) specified.
Like emissions, output names may show “<scenario_name>” in some form of “underscore” case. For example, “Bills” may become “bills”.
Annual Name |
Annual Units |
Notes |
---|---|---|
report_utility_bills.<scenario_name>_coal_energy_usd |
$ |
Scenario annual energy charges for coal. |
report_utility_bills.<scenario_name>_coal_fixed_usd |
$ |
Scenario annual fixed charges for coal. |
report_utility_bills.<scenario_name>_coal_total_usd |
$ |
Scenario annual total charges for coal. |
report_utility_bills.<scenario_name>_electricity_energy_usd |
$ |
Scenario annual energy charges for electricity. |
report_utility_bills.<scenario_name>_electricity_fixed_usd |
$ |
Scenario annual fixed charges for electricity. |
report_utility_bills.<scenario_name>_electricity_pv_credit_usd |
$ |
Scenario annual production credit (negative value) for PV. |
report_utility_bills.<scenario_name>_electricity_total_usd |
$ |
Scenario annual total charges for electricity. |
report_utility_bills.<scenario_name>_fuel_oil_energy_usd |
$ |
Scenario annual energy charges for fuel oil. |
report_utility_bills.<scenario_name>_fuel_oil_fixed_usd |
$ |
Scenario annual fixed charges for fuel oil. |
report_utility_bills.<scenario_name>_fuel_oil_total_usd |
$ |
Scenario annual total charges for fuel oil. |
report_utility_bills.<scenario_name>_natural_gas_energy_usd |
$ |
Scenario annual energy charges for natural gas. |
report_utility_bills.<scenario_name>_natural_gas_fixed_usd |
$ |
Scenario annual fixed charges for natural gas. |
report_utility_bills.<scenario_name>_natural_gas_total_usd |
$ |
Scenario annual total charges for natural gas. |
report_utility_bills.<scenario_name>_propane_energy_usd |
$ |
Scenario annual energy charges for propane. |
report_utility_bills.<scenario_name>_propane_fixed_usd |
$ |
Scenario annual fixed charges for propane. |
report_utility_bills.<scenario_name>_propane_total_usd |
$ |
Scenario annual total charges for propane. |
report_utility_bills.<scenario_name>_total_usd |
$ |
Scenario annual total charges. |
report_utility_bills.<scenario_name>_wood_cord_energy_usd |
$ |
Scenario annual energy charges for wood cord. |
report_utility_bills.<scenario_name>_wood_cord_fixed_usd |
$ |
Scenario annual fixed charges for wood cord. |
report_utility_bills.<scenario_name>_wood_cord_total_usd |
$ |
Scenario annual total charges for wood cord. |
report_utility_bills.<scenario_name>_wood_pellets_energy_usd |
$ |
Scenario annual energy charges for wood pellets. |
report_utility_bills.<scenario_name>_wood_pellets_fixed_usd |
$ |
Scenario annual fixed charges for wood pellets. |
report_utility_bills.<scenario_name>_wood_pellets_total_usd |
$ |
Scenario annual total charges for wood pellets. |
Quantities of Interest
These outputs require that only a single switch is enabled.
See the Residential HPXML Workflow Generator documentation page (i.e., reporting_measures
section) for more information on how to request quantities of interest outputs.
Annual Name |
Annual Units |
Notes |
---|---|---|
qoi_report.qoi_average_maximum_daily_timing_cooling_hour |
hr |
The average hour (average daily index) for which the total site electricity maximum daily use occurs during the cooling season. |
qoi_report.qoi_average_maximum_daily_timing_heating_hour |
hr |
The average hour (average daily index) for which the total site electricity maximum daily use occurs during the heating season. |
qoi_report.qoi_average_maximum_daily_timing_overlap_hour |
hr |
The average hour (average daily index) for which the total site electricity maximum daily use occurs during the overlap season. |
qoi_report.qoi_average_maximum_daily_use_cooling_kw |
kW |
The total site electricity average maximum daily use during the cooling season (days with average outdoor air drybulb temperature greater than 70F). |
qoi_report.qoi_average_maximum_daily_use_heating_kw |
kW |
The total site electricity average maximum daily use during the heating season (days with average outdoor air drybulb temperature less than 55F). |
qoi_report.qoi_average_maximum_daily_use_overlap_kw |
kW |
The total site electricity average maximum daily use during the overlap season (days with average outdoor air drybulb temperature between 55F and 70F). |
qoi_report.qoi_average_minimum_daily_use_cooling_kw |
kW |
The total site electricity average minimum daily use during the cooling season (days with average outdoor air drybulb temperature greater than 70F). |
qoi_report.qoi_average_minimum_daily_use_heating_kw |
kW |
The total site electricity average minimum daily use during the heating season (days with average outdoor air drybulb temperature less than 55F). |
qoi_report.qoi_average_minimum_daily_use_overlap_kw |
kW |
The total site electricity average minimum daily use during the overlap season (days with average outdoor air drybulb temperature between 55F and 70F). |
qoi_report.qoi_average_of_top_ten_highest_peaks_timing_cooling_hour |
hr |
The average hour (average daily index) for which the total site electricity average of top 10 maximum daily use occurs during the cooling season. |
qoi_report.qoi_average_of_top_ten_highest_peaks_timing_heating_hour |
hr |
The average hour (average daily index) for which the total site electricity average of top 10 maximum daily use occurs during the heating season. |
qoi_report.qoi_average_of_top_ten_highest_peaks_use_cooling_kw |
kW |
The total site electricity average of top 10 maximum daily use during the cooling season (days with average outdoor air drybulb temperature greater than 70F). |
qoi_report.qoi_average_of_top_ten_highest_peaks_use_heating_kw |
kW |
The total site electricity average of top 10 maximum daily use during the heating season (days with average outdoor air drybulb temperature less than 55F). |
qoi_report.qoi_hourly_peak_magnitude_timing_hour |
hr |
The hour (annual index) for which the total site electricity annual peak use occurs. |
qoi_report.qoi_hourly_peak_magnitude_use_kw |
kW |
The total site electricity annual peak use (maximum value). |
Other Timeseries
Other timeseries outputs include zone temperatures/setpoints, airflow rates, weather file data, and user-requested EnergyPlus output variables.
See the Residential HPXML Workflow Generator documentation page (i.e., simulation_output_report
section) for more information on how to request other timeseries outputs.
See the OpenStudio-HPXML Workflow Outputs section on Timeseries Outputs for more information about other timeseries outputs.
Timeseries ResStock Name |
Timeseries BuildStockBatch Name |
Timeseries Units |
Notes |
---|---|---|---|
Time |
time |
Local clock. |
|
TimeDST |
timedst |
Local clock daylight saving time. |
|
TimeUTC |
timeutc |
Local clock coordinated universal time. |
|
Temperature: Attic - Unvented |
temperature__attic_-_unvented__f |
F |
Zone temperatures (in deg-F) for each space (e.g., conditioned space, attic, garage, basement, crawlspace, etc.) plus heating/cooling setpoints. |
Temperature: Attic - Vented |
temperature__attic_-_vented__f |
F |
Zone temperatures (in deg-F) for each space (e.g., conditioned space, attic, garage, basement, crawlspace, etc.) plus heating/cooling setpoints. |
Temperature: Basement - Unconditioned |
temperature__basement_-_unconditioned__f |
F |
Zone temperatures (in deg-F) for each space (e.g., conditioned space, attic, garage, basement, crawlspace, etc.) plus heating/cooling setpoints. |
Temperature: Crawlspace - Unvented |
temperature__crawlspace_-_unvented__f |
F |
Zone temperatures (in deg-F) for each space (e.g., conditioned space, attic, garage, basement, crawlspace, etc.) plus heating/cooling setpoints. |
Temperature: Crawlspace - Vented |
temperature__crawlspace_-_vented__f |
F |
Zone temperatures (in deg-F) for each space (e.g., conditioned space, attic, garage, basement, crawlspace, etc.) plus heating/cooling setpoints. |
Temperature: Garage |
temperature__garage__f |
F |
Zone temperatures (in deg-F) for each space (e.g., conditioned space, attic, garage, basement, crawlspace, etc.) plus heating/cooling setpoints. |
Temperature: Conditioned Space |
temperature__conditioned_space__f |
F |
Zone temperatures (in deg-F) for each space (e.g., conditioned space, attic, garage, basement, crawlspace, etc.) plus heating/cooling setpoints. |
Temperature: Other Heated Space |
temperature__other_heated_space__f |
F |
Zone temperatures (in deg-F) for each space (e.g., conditioned space, attic, garage, basement, crawlspace, etc.) plus heating/cooling setpoints. |
Temperature: Heating Setpoint |
temperature__heating_setpoint__f |
F |
Zone temperatures (in deg-F) for each space (e.g., conditioned space, attic, garage, basement, crawlspace, etc.) plus heating/cooling setpoints. |
Temperature: Cooling Setpoint |
temperature__cooling_setpoint__f |
F |
Zone temperatures (in deg-F) for each space (e.g., conditioned space, attic, garage, basement, crawlspace, etc.) plus heating/cooling setpoints. |
Airflow: Infiltration |
airflow__infiltration__cfm |
cfm |
Airflow rates (in cfm) for infiltration, mechanical ventilation (including clothes dryer exhaust), natural ventilation, whole house fans. |
Airflow: Mechanical Ventilation |
airflow__mechanical_ventilation__cfm |
cfm |
Airflow rates (in cfm) for infiltration, mechanical ventilation (including clothes dryer exhaust), natural ventilation, whole house fans. |
Airflow: Natural Ventilation |
airflow__natural_ventilation__cfm |
cfm |
Airflow rates (in cfm) for infiltration, mechanical ventilation (including clothes dryer exhaust), natural ventilation, whole house fans. |
Weather: Drybulb Temperature |
weather__drybulb_temperature__f |
F |
Weather file data including outdoor temperatures, relative humidity, wind speed, and solar. |
Weather: Wetbulb Temperature |
weather__wetbulb_temperature__f |
F |
Weather file data including outdoor temperatures, relative humidity, wind speed, and solar. |
Weather: Relative Humidity |
weather__relative_humidity__% |
% |
Weather file data including outdoor temperatures, relative humidity, wind speed, and solar. |
Weather: Wind Speed |
weather__wind_speed__mph |
mph |
Weather file data including outdoor temperatures, relative humidity, wind speed, and solar. |
Weather: Diffuse Solar Radiation |
weather__diffuse_solar_radiation__btu/(hr*ft^2) |
Btu/(hr*ft^2) |
Weather file data including outdoor temperatures, relative humidity, wind speed, and solar. |
Weather: Direct Solar Radiation |
weather__direct_solar_radiation__btu/(hr*ft^2) |
Btu/(hr*ft^2) |
Weather file data including outdoor temperatures, relative humidity, wind speed, and solar. |
Zone People Occupant Count: Conditioned Space |
zone_people_occupant_count__conditioned_space |
User-requested EnergyPlus output variable. |
|
Schedule Value: Ceiling_fan |
schedules_ceiling_fan |
||
Schedule Value: Clothes_dryer |
schedules_clothes_dryer |
||
Schedule Value: Clothes_washer |
schedules_clothes_washer |
||
Schedule Value: Cooking_range |
schedules_cooking_range |
||
Schedule Value: Dishwasher |
schedules_dishwasher |
||
Schedule Value: Hot_water_clothes_washer |
schedules_hot_water_clothes_washer |
||
Schedule Value: Hot_water_dishwasher |
schedules_hot_water_dishwasher |
||
Schedule Value: Hot_water_fixtures |
schedules_hot_water_fixtures |
||
Schedule Value: Lighting_garage |
schedules_lighting_garage |
||
Schedule Value: Lighting_interior |
schedules_lighting_interior |
||
Schedule Value: Occupants |
schedules_occupants |
||
Schedule Value: Outage |
schedules_outage |
||
Schedule Value: Plug_loads_other |
schedules_plug_loads_other |
||
Schedule Value: Plug_loads_tv |
schedules_plug_loads_tv |
||
Schedule Value: Vacancy |
schedules_vacancy |